Static Var Generator LV Static Var Generator (SVG/SVG+)Ask PricePhase: Three PhaseVoltage: 400V......690V RMSUsage/Application: harmonic mitigation,fast reactive power compensation,enhanced power quality Phase: Three PhaseVoltage: 400V......690V RMSUsage/Application: harmonic mitigation,fast reactive power compensation,enhanced power qualityOutput Capacity: 50,75,100,125, 150, 200 kVAr(Inductive/Capacitive)Frequency: 50/60 Hz (+/-5%)System Configuration: 3P3W/ 3P4WResponse Time: <= 10ms Clariant Power System Limited’s Static VAR Generator (SVG) is a Step-less Solutions to improve Power Factor.The use of most advanced controllability of 3-Phase 3-Level IGBT based voltage source inverter architecture, CPSL SVG does precise power factor and unbalance correction without the need of any passive power factor correction capacitors. These SVGs are designed in stackable modular configuration for increased resilience, reliability and redundancy.The real-time reference value of the reactive power output of the SVG is precisely calculated in real-time by adjusting waveshape, magnitude and phase angles as per the target power factor entered by the user, and voltage and current values.CPSL SVGs are powered with a sophisticated Artificial Neural Network-based control algorithm to achieve a set power factor, while always working in the background for real-time loss minimization, to achieve improved energy efficiency.Benefits:Bi-directional Reactive Power Compensation (Compensates both Inductive and Capacitive KVAR).Near Unity P.F Correction at all load conditions.Low KVAR capacity dependency on grid fluctuations.Advanced technology and easy to use HMI Monitor with built-in-real-time measuring functionalities.Key Features: System Voltage: 400V to 690V RMSOutput Capacity: 50,75,100,125, 150, 200 kVAr (Inductive/Capacitive), scalable to meet higher capacity requirements.Frequency: Compatible with 50/60 Hz systems, operating within ±5% tolerance.System Configuration: Available in 3P3W and 3P4W configurations; single-phase option is also available.Dynamic Response Time: Ultra-fast correction with a response time of ≤10ms.CT Configuration:Supports both closed-loop and open-loop configurations for versatile installation.Step-less Compensation Range :-100 KVAR to +125 KVARSemiconductor Devices : IGBT's (3-Level Topology)Operating Temperature Range: 0 to 50°CParallel Communication: CAN Bus / Mini USBParalleling Operation: Upto 50 ModulesController & Control Method: ARM based MCU with Adaptive Artificial Neural Network (ANN) Applications: Ideal for industrial and commercial establishments looking for efficient reactive power compensation and harmonic mitigation solutions. Suitable for dynamic load applications where fast response and power quality improvement are critical.This highly reliable and efficient LV Static VAR Generator is designed to enhance power quality, reduce energy losses, and ensure smooth operation of sensitive equipment.know more2855436447262Get Best PriceCall Now MV Static VAR Compensators / Generators (STATCOM/SVG)Ask PricePhase: Three PhaseVoltage: 3.3kV......35kV +-10%Usage/Application: Reactive power controls,P.F control, voltage regulation & unbalance control Phase: Three PhaseVoltage: 3.3kV......35kV +-10%Usage/Application: Reactive power controls,P.F control, voltage regulation & unbalance controlAuxiliary Power: 380VAC, 220VAC / 220VDCFrequency: 50/60HzOutput Capacity: +/- 0.1Mvar...+/- 200Mvar (Capacitive/Inductive)Starting Power: +/- 0.005MvarResponse Time: <= 5ms We provide IGBT based power electronic active dynamic unit called STATCOM.STATCOM is a Step less Variable Source of Reactive Power that can provide both Capacitive and Inductive power. It has distinct advantages and is ideal for demanding applications such as those prevailing during highly fluctuating load conditions and varying reactive power requirements of Grid connected power generating units. STATCOM for Grid Connected Solar Plants can provide Dynamic Reactive Power support for voltage Control.The purpose of the Dynamic compensation system at solar power exporting facility is to minimize import of reactive power both inductive and capacitive from the Grid.Statcom has multifold capabilities of:Reactive Power Compensation, Harmonic Filtration, flicker control, unbalance control etc.Step-less compensation capable of injecting capacitive or inductive power on a real-time basis.Voltage and Reactive Power control for stable power system operationReduced voltage fluctuations.Key Features: Rated Voltage: 3.3kV to 35kV ±10%Frequency: Supports 50/60Hz with short-term fluctuation toleranceOutput Capacity: ±0.1Mvar to ±200Mvar (Capacitive/Inductive)Starting Power: ±0.005MvarUltra-fast Response: Response time ≤ 5msAuxiliary Power Supply: Available in 380VAC, 220VAC, or 220VDCAdvanced Communication Interfaces: Ethernet, RS485, CAN, and Optical Fiber for seamless connectivityCooling Modes: Options for both water cooling and air cooling, ensuring operational flexibilityRemote Operation: Supports remote monitoring and control for user convenienceModular Design: Compact, easy-to-install, and scalable for future requirementsFunctional Capabilities: Dynamic reactive power controlPower factor (P.F.) optimizationVoltage stabilization and regulationUnbalance control for reliable grid operationknow more2855436397733Get Best PriceCall Now
Explore More Categories HT Capacitor Bank 2 Products Power Factor Control Relays 2 Products LT Capacitors 2 Products HT Capacitors 2 Products Water Cooled Capacitors 2 Products Series Reactors 2 Products Capacitor Switching Contactors 1 Product Power Quality Analysis Services 1 Product View Complete Range >
x Provide Us More Details Enter your name Purpose of Requirement: Reselling End Use Raw Material We recommend you to enter details of your requirement to get quick quotations.