TrustSeal Verified

HT Automatic Harmonic Power Factor Correction Panel

Medium Voltage Fixed/Automatic PF Improvement Capacitor Bank (Indoor Type)

Ask Price

Medium Voltage Fixed/Automatic PF Improvement Capacitor Bank  (Indoor Type)
  • Usage/Application: Chemical Industry, Cement Plant, Sugar Plant, Textile, Hospital
  • Cable Entry: Bottom, Top
  • Power Source: Electric
  • Minimum Order Quantity: 1 Piece
  • Usage/Application: Chemical Industry, Cement Plant, Sugar Plant, Textile, Hospital
  • Cable Entry: Bottom, Top
  • Power Source: Electric
  • Switching device: Vacuum Contactor / Capacitor Switching
  • System Voltage: 3.3, 6.6.... 33 KV
  • Installation: Indoor / Outdoor
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Delivery Time: 1- 2 Weeks
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer)
  • Delivery Time: 1- 2 Weeks

All industrial and commercial sectors which are bulk consumers of Electricity need correctly and optimally designed PFC Systems to save maximum on energy bills and to avoid penalties on Harmonics.

With advanced methodology, Clariant Power System Limited design and manufactures customized Power Factor Correction Systems for Medium Voltage & High Voltage applications which provide combined solution for Power Factor Improvement and Harmonic Mitigation with convincing Payback/ROI.

  • MV APP Type Capacitor for P.F Improvement
  • MV Single Phase or Three Phase Iron Core or Air Core Series Reactor for Inrush Current Limiting & Harmonic Filtration
  • Panel/Structure Mounted Off Load Isolator with/without Earth Switch
  • Indoor/Outdoor type Vacuum Contactor for Capacitor Switching in case of APFC system
  • Residual Voltage Transformer (RVT) and Neutral Current Transformer (NCT) for unbalance protection along with Neutral Displacement Relay (NDR) & Current Monitoring Relay (CMR)


Technical Specifications:

  • System Voltage : 3.3, 6.6.... 33 KV
  • System Configuration : Single or Double Star
  • Rated KVAR : 450 KVAR.....20 MVAR
  • Switching Device : Vacuum Contactor / Capacitor Switching
  • Type tested for : 6.6KV and 11 KV 
  • Harmonic filtration : With Tuned/Detuned/Tapped Tuned Harmonic Filter Reactors
  • Tuned to :3rd, 5th, 7th, 11th or 13th order harmonics
  • Type : Fix / Automatic
Benefits :
  • Auto Controlled Voltage support for Grid
  • Reduction in line losses
  • Reduced electrical burden on cables and other electrical Components
  • Improved KVA capacity utilization of Power Transformers
  • Reduced Voltage Drops, Improved Voltage Regulation
  • Full utilization of installed capacity of generation, transmission and distribution leading to reduced fuel consumption
know more

Explore More Categories

x

Send us a Quick Message

country flag
x

Provide Us More Details

Purpose of Requirement:

Reselling End Use Raw Material

We recommend you to enter details of your requirement to get quick quotations.
Back
company logo

Clariant Power System Limited